Dan Ferris writes:
 > 
 > Was this a trial and error method, and do you have the tuner type 50?
 >

Yes, and yes (type=50).  I have no clue what those numbers means.  I
just added trace codes where frequency setting was taking place,
observed what was being set when I set the frequency 1Mhz off (which
was painfully figured out by try and error) and noticed that a
particular data was off by 16.  That value in the table was being
added to whatever calculation it was doing so it was a convenient
place to make an adjustment.  I'm hoping a developer can implement a
right fix given this info.

Hiroto



-------------------------------------------------------