will something like " show interfaces terse | match -0/1/ | match down" work for you ?
(assuming that the PIC is in FPC0/Slot1 On 1/23/07, Josh L. Richesin <[EMAIL PROTECTED]> wrote: > I have a bunch of t1's ds3's and oc3's hanging off of this interface. > Is there a command that would show me which ones might be down? > > Thanks, > Josh > > > -----Original Message----- > From: Jared Gull [mailto:[EMAIL PROTECTED] > Sent: Tuesday, January 23, 2007 9:33 AM > To: Josh L. Richesin; [email protected] > Subject: Re: [j-nsp] OC12 PIC > > Josh, > > What is the current state of the interface (i.e. show interface so-x/y/z > extensive)? If the PIC is operational and the circuit is up it should be > green. > > -Regards, > > Jared > --- "Josh L. Richesin" <[EMAIL PROTECTED]> wrote: > > > Hello, > > I have a Juniper m10i and I just notcied that the status light on the > > pic is amber. Is this normal? I don't remember it being amber. I > > did a show system alarms and didn't see any alarms. > > > > Thanks, > > Josh > > > > > > > > _______________________________________________ > > juniper-nsp mailing list [email protected] > > https://puck.nether.net/mailman/listinfo/juniper-nsp > > > > > > > ________________________________________________________________________ > ____________ > Get your own web address. > Have a HUGE year through Yahoo! Small Business. > http://smallbusiness.yahoo.com/domains/?p=BESTDEAL > > > > _______________________________________________ > juniper-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/juniper-nsp > -- Erdem _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp