Hello,

FWLF1613xx are multirate sonet-only SFP's. They can do OC3/OC12/OC48.
However they wont work with ethernet applications.

However finisar offers sfp's which are truely multirate for any
application (ethernet or sonet from OC3 to OC48 incl. gigabit ethernet).

In general any 3rd party SFP works fine with juniper routers since there
is no "pseudo quality-ID" feature as with cisco.

Regards,
Jonas Frey


On Wed, 2008-06-11 at 17:55, Chuck Anderson wrote:
> Does anyone have any experience, good or bad, with using 3rd party 
> DWDM SFPs in M120 or M10i Gigabit Ethernet PICs?  Specifically, I'm 
> looking at using these SFPs:
> 
> Finisar FWLF1631xx 2.67 Gigabit RoHS Compliant DWDM SFP with APD 
> Receiver:
> 
> http://www.finisar.com/product-124-2.67_Gigabit_RoHS_Compliant_DWDM_SFP_with_APD_Receiver_(FWLF1631xx)
> 
> 
> With two each of the above in these PICs:
> 
> M120:  PC-8GE-TYPE3-SFP-IQ2
> M10i:  PE-4GE-TYPE1-SFP-IQ2
> 
> Thanks.
> _______________________________________________
> juniper-nsp mailing list [email protected]
> https://puck.nether.net/mailman/listinfo/juniper-nsp


_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp

Reply via email to