> -----Original Message----- > From: [email protected] [mailto:juniper-nsp- > [email protected]] On Behalf Of snort bsd > Sent: Friday, August 06, 2010 3:01 PM > To: juniper-nsp > Subject: [j-nsp] virtual-chassis and interfaces > > Hi all: > > With virtual-chassis, after I login, I only see interfaces (under > stanza "interfaces") on master, not those interfaces on the back up > mode or line card mode. > > How could I configure those interfaces that are not on master? do I > have to login each physical switch in order to configure those > interfaces?
They might not necessarily show up in the configuration until you actually define them... it depends on how they were brought into the virtual-chassis. However if your Virtual-Chassis is set up correctly, they should still show up when you do a 'show interfaces terse'. The FPC portion of the interface naming convention is what is used to identify the interfaces on a given virtual-chassis member. In other words, interfaces on member-id 2 will show up in 'show interfaces terse' as ge-2/x/x or xe-2/x/x. You can verify that your virtual-chassis is working correctly by doing a 'show virtual-chassis status', or even a 'show chassis hardware' will give you a clue as to whether or not all the members are shown in the virtual-chassis. HTHs. Stefan Fouant, CISSP, JNCIEx2 www.shortestpathfirst.net GPG Key ID: 0xB5E3803D _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp