Hello,

Tobias Heister (Thu 2013-01-10 14:31:40 +0100) :
> We have not yet found an EX platform (tried
> 2200/3200/4200/4500/8200) which supported policing on egress (using
> Firewall filters and policing, never tried using QoS)

I don't know for the OP needs but for shure EX4200 does not have:

- syslog in firewall filters
- tcp flags (e. g. established) in firewall filters

in egress (physical or VLAN interface). 

Juniper confirmed that this is a hardware limitation. That was the
reason we went MX.

Cheers,

-- 
Emmanuel Halbwachs                              Observatoire de Paris
Resp. Réseau/Sécurité                           5 Place Jules Janssen
tel  : +33 1 45 07 75 54                         F 92195 MEUDON CEDEX
                               véhicules : 11 av. Marcellin Berthelot
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp