l2circuit is not supported as that requires a two label stack to work. EX4200's can only switch a 1 label stack. Any traffic passed in P/LSR fashion that has more than 1 label in the stack gets dropped transparently from what I have seen, regardless of what the control plane/RE said.
ccc/remote-interface-switch like in the link I sent earlier is the only way that works as far as I have seen. This is probably because of the 1:1 mapping of LSP to ccc direction. On Tue, May 12, 2015 at 6:12 PM, Raphael Mazelier <[email protected]> wrote: > > > Le 12/05/15 05:59, Mark Tees a écrit : >> >> Hi Victor, >> >> The only way I am aware of that works with ex4200s is tunnelling over >> MPLS. This would require MPLS on the backbone to work. >> >> >> http://www.juniper.net/techpubs/en_US/junos13.2/topics/task/configuration/mpls-ex-series-provider-edge-switches-ccc-cli.html >> > > Hum on my test even l2circiut (ccc) is not working on EX4200. > > -- > Raphael Mazelier > > _______________________________________________ > juniper-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/juniper-nsp -- Regards, Mark L. Tees _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp