❦ 18 avril 2017 21:51 +0200, Raphael Mazelier <[email protected]> :
>> Is this the case for chassis MX104 and 80? Is your recommendation to run
>> with indirect-next-hop on them as well?
>>
>
> Correct me if I'm wrong but I think this is the default on all the MX
> since a long time. There as no downside afaik.
Documentation says:
> By default, the Junos Trio Modular Port Concentrator (MPC) chipset on
> MX Series routers is enabled with indirectly connected next hops, and
> this cannot be disabled using the no-indirect-next-hop statement.
--
Harp not on that string.