> The other problem is that when I run a DRC check it says a number of
> pads are unconnected which are not unconnected.  I did not have this
> problem when I ran a DRC a little while back, and the only thing I've
> done since then is increase the size of my vias and move some runs
> around.  It would also plot without problems before.

I've seen something similar.   Have you checked the connectivity using
the net highlighter tool?   What I found was that what was previously
one logical track had become two logical tracks which were still
connected visually.   Only one of the logical tracks would be on the
expected net, so I would delete the other and recreate the missing
section.   Hope that makes sense!

Regards,

Robert.



-- 