Hi, First question: all GND tracks must be connected as though there isn't any zone. Once the zone is created, the tacks on the same area as the zone are sunk in the zone. The tracks still exists, but the result is a copper zone anyway.
If tracks are connected to a zone with a via, they will be connected on the real pcb, but they will not be logically connected. So, pcbnew will mark these tracks as not connected. Second question: preferences->colors will show or not show layers. This feature is in the manual :-) Regards, Pedro. > Hi. > I am about to complete my first KiCad project and I really like the > Software. The only thing missing is the ground connections. Now I > wanted to create filled areas for this purpose and I succeeded in > doing so. The areas are also recognized as "GND" when I right-click on > them. Gnd-pads have been connected via the "thermal" option to the > area during the filling process. > The problem is that KiCad does not consider the pads to be connected > although they ARE connected as a matter of fact via the area. Can > someone tell me what I have to do to make KiCad see the connection? > > One more question: is it possible to graphically deactivate layers? It > would be very useful to see just the top or just the bottom layer but > the only way I found to achieve that is by using the print => preview > function. > > Any help is greatly appreciated!