Thank you for the fast and helpful answers - joining this group has
already paid for me!


--- In [email protected], Pedro Martín <[EMAIL PROTECTED]> wrote:
>
> Hi,
> 
> First question: all GND tracks must be connected as though there
isn't any 
> zone. Once the zone is created, the tacks on the same area as the
zone are 
> sunk in the zone. The tracks still exists, but the result is a
copper zone 
> anyway.
> 
> If tracks are connected to a zone with a via, they will be connected
on the 
> real pcb, but they will not be logically connected. So, pcbnew will
mark 
> these tracks as not connected.
> 
> Second question: preferences->colors will show or not show layers. This 
> feature is in the manual :-)
> 
> Regards,
> Pedro.
> 
> > Hi.
> > I am about to complete my first KiCad project and I really like the
> > Software. The only thing missing is the ground connections. Now I
> > wanted to create filled areas for this purpose and I succeeded in
> > doing so. The areas are also recognized as "GND" when I right-click on
> > them. Gnd-pads have been connected via the "thermal" option to the
> > area during the filling process.
> > The problem is that KiCad does not consider the pads to be connected
> > although they ARE connected as a matter of fact via the area. Can
> > someone tell me what I have to do to make KiCad see the connection?
> >
> > One more question: is it possible to graphically deactivate layers? It
> > would be very useful to see just the top or just the bottom layer but
> > the only way I found to achieve that is by using the print => preview
> > function.
> >
> > Any help is greatly appreciated!
>


Reply via email to