Greg,

 

Well….

I’m so embarrassed! That was it. Thanks again for your help.

 

Bob

 

 

From: [email protected] [mailto:[email protected]] On 
Behalf Of Greg Dyess
Sent: Wednesday, June 24, 2009 12:23 PM
To: [email protected]
Subject: Re: [kicad-users] Bad Bus Label error message when making netlist

 






Try changing the label to A_BUS[0..15] instead of A_BUS[0,15]  (Note the ".." 
instead of ",").

 

In addition, I will load up your schematic and try to see what I can see.

 

Greg

 

  _____  

From: Bob Shaffer <[email protected]>
To: [email protected]
Sent: Wednesday, June 24, 2009 9:13:47 AM
Subject: RE: [kicad-users] Bad Bus Label error message when making netlist [1 
Attachment]

[ 
<http://us.mg4.mail.yahoo.com/dc/blank.html?bn=1357.22&.intl=us&.lang=en-US#TopText>
 Attachment(s) from Bob Shaffer included below] 

Greg,

I appreciate you taking the time to help me!

 

The attached files represent a simple test design that illustrate my problem. 
When I try to connect the two sheets together by drawing a Bus between 
A_BUS[0,15] on Sheet A to A_BUS[0,15] on Sheet B I get a popup error message 
“Bad Bus Label”. If I ignore the message and attempt to generate a netlist, I 
get the same error message.

 

Bob

 

 

From: [email protected] [mailto:[email protected]] On 
Behalf Of Greg Dyess
Sent: Wednesday, June 24, 2009 9:23 AM
To: [email protected]
Subject: Re: [kicad-users] Bad Bus Label error message when making netlist

 





My initial guesses would be:

1. You used a local label instead of a global label or net name.

2. Somehow numbers were not the last characters in the individual nets or the 
bus was not the prefix of the net names.

3. Buses in KiCAD are not like computer busses.  Only nets with the same prefix 
followed by numbers are allowed in the bus.  A0, A1, A2 in bus A[0..2] is a 
valid bus but WR, RD, CLK in bus Control is not valid.

 

(I did all of the above starting out)

It's difficult to analyze without seeing what you have done.  If you email me 
directly with the archived project files I can load it up and see.

 

Greg

  _____  

From: mmabshaffer <[email protected]>
To: [email protected]
Sent: Tuesday, June 23, 2009 5:02:04 PM
Subject: [kicad-users] Bad Bus Label error message when making netlist

I just tried using KiCad for capturing a schematic and all went well until I 
tried to generate the netlist. I get a "Bad Bus Label" error popup message for 
each bus. The design is a hierarchical design with busses going between sheets. 
Can anyone give me a hint as to what I am doing wrong?



------------------------------------

Please read the Kicad FAQ in the group files section before posting your 
question.
Please post your bug reports here. They will be picked up by the creator of 
Kicad.
Please visit http://www.kicadlib.org <http://www.kicadlib.org/>  for details of 
how to contribute your symbols/modules to the kicad library.
For building Kicad from source and other development questions visit the 
kicad-devel group at http://groups.yahoo.com/group/kicad-develYahoo! Groups 
Links



 

 

Attachment(s) from Bob Shaffer 

1 of 1 File(s) 

Image removed by sender.

TestBoard.zip 
<http://d.yimg.com/kq/groups/16027698/1772850888/name/TestBoard.zip> 

 

 



<<~WRD000.jpg>>

<<image001.jpg>>

<<image002.jpg>>

Reply via email to