Your attachment ended up inthe attachments folder and a link was generated to the message.
Have a very close look at the track to the left of the pad with the error arrow. It is very close to the pad clearance line,and it may be a little too close. As a test make that pad smaller and or reduce it's clearance zone and see if that clears the problem. Andy On Fri, 04 Sep 2009 12:09:11 +0100 Robert <[email protected]> wrote: > I have the minimum track spacing set to 0.3mm. After a DRC check on my > board design PCBNew does not mark surface mount pads that are more than > 0.3mm apart (as expected), but it does mark a through-hole pad that is > 0.6mm away from a surface mount pad, complaining that the pads are too > close. Why is this? > > I'm not sure if attachments work, but if they do I've provided one and > made it as small as possible. Note that the DRC lines on the two > adjacent surface mount pads (which pass the DRC) intersect but do not > intersect the pads themselves, but the through-hole pad fails the DRC > even though its DRC line only just touches the DRC line of the surface > mount pad above it. > > Regards, > > Robert. > > > > > > ------------------------------------ > > Please read the Kicad FAQ in the group files section before posting your > question. > Please post your bug reports here. They will be picked up by the creator of > Kicad. > Please visit http://www.kicadlib.org for details of how to contribute your > symbols/modules to the kicad library. > For building Kicad from source and other development questions visit the > kicad-devel group at http://groups.yahoo.com/group/kicad-develYahoo! Groups > Links > > >