Your attachment ended up inthe attachments folder and a link was
generated to the message.

Have a very close look at the track to the left of the pad with the
error arrow. It is very close to the pad clearance line,and it may be a
little too close. 

As a test make that pad smaller and or reduce it's clearance zone and
see if that clears the problem.

Andy
 


On Fri, 04 Sep 2009 12:09:11 +0100
Robert <[email protected]> wrote:

> I have the minimum track spacing set to 0.3mm.   After a DRC check on my
> board design PCBNew does not mark surface mount pads that are more than
> 0.3mm apart (as expected), but it does mark a through-hole pad that is
> 0.6mm away from a surface mount pad, complaining that the pads are too
> close.   Why is this?
> 
> I'm not sure if attachments work, but if they do I've provided one and
> made it as small as possible.   Note that the DRC lines on the two
> adjacent surface mount pads (which pass the DRC) intersect but do not
> intersect the pads themselves, but the through-hole pad fails the DRC
> even though its DRC line only just touches the DRC line of the surface
> mount pad above it.
> 
> Regards,
> 
> Robert.
> 
> 
> 
> 
> 
> ------------------------------------
> 
> Please read the Kicad FAQ in the group files section before posting your 
> question.
> Please post your bug reports here. They will be picked up by the creator of 
> Kicad.
> Please visit http://www.kicadlib.org for details of how to contribute your 
> symbols/modules to the kicad library.
> For building Kicad from source and other development questions visit the 
> kicad-devel group at http://groups.yahoo.com/group/kicad-develYahoo! Groups 
> Links
> 
> 
> 

Reply via email to