I do not remember a CID wait delay in the KX-TVS200. I do know that in night mode when our KX-TVS200 picks up all calls, we log no CID on the the two lines that have CID because the TVS picks up too early because KX-TD1232 DID can not delay one ring. Does anyone know if the earlier KX-TVS systems have a CID wait delay parameter?

Paul H. Gusciora
San Rafael, CA

----- Original Message -----
From: "Bob [EMAIL PROTECTED]" <[EMAIL PROTECTED]>
To: "CP" <[EMAIL PROTECTED]>, <[EMAIL PROTECTED]>,
        <[EMAIL PROTECTED]>
Subject: Re: KX-T: Re: TVS50 not answering for 3 rings
Date: Wed, 17 Mar 2004 00:43:17 -0400

ALso, don't forget to turn off the Caller ID wait delay inside the TVS-50...
Don't have my cheat sheet with me right now, but that one always nails ya.

Bob

---------- Original Message -----------
From: "CP" <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>, <[EMAIL PROTECTED]>
Sent: Tue, 16 Mar 2004 22:52:20 -0500
Subject: KX-T: Re: TVS50 not answering for 3 rings

Henry,

 check DIL 1-1 day and night mode. 407/408
 That should be to 165 for the AA  to answer immediately.

 check IRNA (intercept routing) day/night 409/410 for trunk group
 intercepting.
 That should be to 165 for calls to go to AA after 3 or 4 or whatever
 rings program and program 203 sets the number of rings for intercept
 (3 is shortest)

Charles

 ----- Original Message -----
 From: "hrobertelli" <[EMAIL PROTECTED]>
 To: <[EMAIL PROTECTED]>
 Sent: Tuesday, March 16, 2004 9:55 PM
 Subject: KX-T: TVS50 not answering for 3 rings

 > I know the answer is simple but I am missing something.
 >
 > Hardware:
 > KX-TD816-7 and TVS 50 newly installed.
 >
 > The AA answers the inbound calls after three rings.  No matter what I do
 > I can not get it to answer on the first ring.  When I pick up the
 > intercom line and dial 165 the TVS answers immediately.
 >
 > When the call comes in the respective TD816 CO light is glowing.  But
 > the call is not answered for three by the TVS 50.
 >
 > I attached the TVS to a new defaulted KSU, programmed integration to
 > port 8, directed the inbound to 165.  On the first try it answered after
 > one ring on subsequent tries the TVS answered after three rings.  All
 > Port settings on the TVS are 0 seconds.
 >
 > Help.what am I missing?
 >
 > Sincerely,
 > Henry
 >
 > Henry C. Robertelli
 > Comvox Systems
 > Jacksonville Florida
 >
 > _________________________________________________________________
 > KX-T Mailing list --- http://kxthelp.com/
 > Subscription changes: http://kxthelp.com/mailman/listinfo/kxt
 >
 >

 _________________________________________________________________
 KX-T Mailing list --- http://kxthelp.com/
 Subscription changes: http://kxthelp.com/mailman/listinfo/kxt
------- End of Original Message -------