I received a call from a customer about an hour away. He has a small business with four CO lines and eight 7700 series stations and two 7895 cordless sets. I installed a KX-TA624 about seven years ago with one expansion card [6 x 16]. No problems since till now. His complaint was Line 4 light was always lit and the line was dead when he tried to access it. I had him reboot the KSU. The first call that comes in goes to Line 4 [Lines 1,2,3 not busy]. After the call is completed, line 4 stays lit and all calls properly route to Line1 and if busy to 2, etc, the Line 4 light stays lit and that line is not usable. I have not been on site yet, thought maybe some previsit ideas might help. Thanks
Bob Bruskin Halstead Electronics Ltd. Cell: 914-403-1537 _________________________________________________________________ KX-T Mailing list --- http://kxthelp.com/ Subscription changes: http://kxthelp.com/mailman/listinfo/kxt