Victor,

(Victor, Sorry you got duplicates, I meant to send this to the list the first 
time because it might help others.)

I had already gotten the inittab change, but what I  learned after posting the 
message by searching the list archives for  "serial" is that there are several 
files named *.ser that have 

all the serial changes in them.

The secret is hiding in the second line of the file syslinux.ser:

# This configures Bering-uClibc with only serial consoles. Two steps are needed:
# Rename syslinux.ser as syslinux.cfg, and configdb.ser as configdb.lrp
serial 0 19200
display syslinux.dpy
timeout 0 
append reboot=bios
default linux initrd=initrd.lrp init=/linuxrc rw root=/dev/ram0 
console=ttyS0,19200n8 LEAFCFG=/dev/fd0u1680:msdos

The step I missed was renaming configdb.ser as configdb.lrp.

While I don't have everything set up yet, this very message is  being typed 
online via the new version of the router.

Thanks to the authors, who so very kindly anticipated my problem and provided a 
solution!!

Tim


________________________________
From: Victor McAllister <victo...@sonic.net>
To: leaf-user@lists.sourceforge.net
Sent: Sun, July 25, 2010 4:28:38 PM
Subject: Re: [leaf-user] Problems with Bering uclibc 3.1.1 beta3 on Soekris


/etc/inittab

#tty1::respawn:/sbin/getty 38400 tty1
#tty2::respawn:/sbin/getty 38400 tty2

Victor
------------------------------------------------------------------------------
This SF.net email is sponsored by Sprint
What will you do first with EVO, the first 4G phone?
Visit sprint.com/first -- http://p.sf.net/sfu/sprint-com-first
------------------------------------------------------------------------
leaf-user mailing list: leaf-user@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/leaf-user
Support Request -- http://leaf-project.org/

Reply via email to