Paul,

If you're going to be going to the Red Hat 7.2, you need to specify the
chandev parameter twice, once as CHANDEV= and once as chandev=

Mark Post

-----Original Message-----
From: paultz [mailto:[EMAIL PROTECTED]]
Sent: Wednesday, April 03, 2002 7:20 PM
To: [EMAIL PROTECTED]
Subject: ESCON CTCs for a RH 7.2 LPAR install


I saw this topic covered in prior posts, but am unable to discernt the
correct parms for my initial tape IPL.

In RH 6.2  I specify: ctc=noauto ctc=0,0x3220,0x3221,escon0 .... and
that works.

Same LPAR, RH 7.2, I tried the old parm plus tried Mark Post's
suggestion for CHANDEV=escon0,0x3220,0x3221 ... and neither work.

ifconfig escon0 results in 'error fetching interface information: device
not found'.

Does someone have a parm file for escon ctc's that they could share?

Thanks,
Paul

Reply via email to