Paul, If you're going to be going to the Red Hat 7.2, you need to specify the chandev parameter twice, once as CHANDEV= and once as chandev=
Mark Post -----Original Message----- From: paultz [mailto:[EMAIL PROTECTED]] Sent: Wednesday, April 03, 2002 7:20 PM To: [EMAIL PROTECTED] Subject: ESCON CTCs for a RH 7.2 LPAR install I saw this topic covered in prior posts, but am unable to discernt the correct parms for my initial tape IPL. In RH 6.2 I specify: ctc=noauto ctc=0,0x3220,0x3221,escon0 .... and that works. Same LPAR, RH 7.2, I tried the old parm plus tried Mark Post's suggestion for CHANDEV=escon0,0x3220,0x3221 ... and neither work. ifconfig escon0 results in 'error fetching interface information: device not found'. Does someone have a parm file for escon ctc's that they could share? Thanks, Paul