On Friday, 12/20/2002 at 02:20 EST, Mark Post <[EMAIL PROTECTED]> wrote:
> Paul,
>
> Glad you could jump in here, since you can speak with a whole lot more
> authority on this than most.  I did hear back from my co-worker, and he
> provided a somewhat different set of definitions that also seem to work:
>
> IODEVICE ADDRESS=(1000,128),CUNUMBR=(B000),STADET=Y,UNIT=SCTC
> CNTLUNIT CUNUMBR=B000,PATH=(B0),UNITADD=((00,128)),UNIT=SCTC

Mark, UNIT=SCTC is needed for ESCON-attached routers.  For parallel
attachment, use UNIT=3088 on CNTLUNIT and UNIT=CTC on IODEVICE.

Alan Altmark
Sr. Software Engineer
IBM z/VM Development