On 6/3/15, 2:39 PM, "Dazzo, Matt" <[email protected]> wrote:

>MDISK 191 3390 0001 0020 LN2C17 MR READ WRITE MULTIPLE
>    
> MDISK 192 3390 0021 0980 LN2C17 MR READ WRITE MULTIPLE
>      
>
>Activate the new user direct
>
>LOGON LNXMAINT    
>HCPLNM108E LNXMAINT 0191 not linked; volid LN44A9 not mounted
>HCPLNM108E LNXMAINT 0192 not linked; volid LN44A9 not mounted
Strange that your directory entry specifies volume LN2C17 but LNXMAINT is
looking for volume LN44A9. Because it cannot find that volid, it cannot
give you a 191 or 192 minidisk.


> I do (att xxx * 191) Start the format, the format process formats the
>entire disk not just the first 20 cyl of 191.


What are you attaching as 191 and why? The MDISK statements mean that when
you logon to LNXMAINT it will (should) have a 191 and 192 disk there for
you to format. However, the mismatch in VOLIDs is puzzling. On MAINT, what
does #CP Q DA LN44A9 and #CP Q DA LN2C17 report?

Neale