> I'm afraid I'm not familar with the AudioUnits API, but I dont/think/ this > situation requires the instrument to inform the host, it should just be > able to damp (slew rate limit) the control, shouldn't it? The result from > playing back automation data will be the same, so no harm done.
Well, if the host is auto-generating a UI, or it is, in-fact tracking the values itself (no get() method) then it needs to know. > > Also to think about - what if the host sends a bad value, and a control > > wants to reject it? Ahh, asyncronicity. I guess for this case the plugin > > sends back some FAIL event or simpler sends back a CTRL_CHANGE with the old > > value (or the min/max if the host has gone too far). > > Bad value? LADSPA has the concept that there are no bad values, the plugin > has to accept anything. It can choose to ignore it, but it mustn't > segfault or whatever. I was more thinking that some controls would disable certain functions, or limit other controls. Assuming that there is no get() method for a control, and the host knows the value by remembering, then the plugin does need to alert the host if it 'ignores' something, or the host will have the wrong value. > England, UK. GMT+1. I'm not a mornings person though ;) Ahh. Sunny England. For the record, I am in the San Francisco area. Tim