Hi,

On Thu, Oct 15, 2009 at 08:42:02AM -0500, Alex Dean wrote:
> 
> On Oct 15, 2009, at 8:29 AM, fengyandong wrote:
> 
> > Yes,  if the power of the node is pulled out,  the stonith device  
> > can not
> > work.
> 
> I'm using iLO2 as my stonith device, which relies on the power of the  
> host machine.  When pulling the power cables of the primary node, I've  
> observed that the secondary node will attempt to stonith the primary  
> node.  This fails because iLO2 also loses power when the host's power  
> is cut.  The secondary node will retry indefinitely until stonith  
> succeeds, and will not become primary until then.  When I restore  
> power to the old primary, it is reset by the secondary, and the  
> secondary then proceeds to start resources.

Yes, that's to be expected.

Thanks,

Dejan