Hi, On Thu, Oct 15, 2009 at 08:42:02AM -0500, Alex Dean wrote: > > On Oct 15, 2009, at 8:29 AM, fengyandong wrote: > > > Yes, if the power of the node is pulled out, the stonith device > > can not > > work. > > I'm using iLO2 as my stonith device, which relies on the power of the > host machine. When pulling the power cables of the primary node, I've > observed that the secondary node will attempt to stonith the primary > node. This fails because iLO2 also loses power when the host's power > is cut. The secondary node will retry indefinitely until stonith > succeeds, and will not become primary until then. When I restore > power to the old primary, it is reset by the secondary, and the > secondary then proceeds to start resources.
Yes, that's to be expected. Thanks, Dejan > alex > _______________________________________________ > Linux-HA mailing list > [email protected] > http://lists.linux-ha.org/mailman/listinfo/linux-ha > See also: http://linux-ha.org/ReportingProblems _______________________________________________ Linux-HA mailing list [email protected] http://lists.linux-ha.org/mailman/listinfo/linux-ha See also: http://linux-ha.org/ReportingProblems