Read access to the SPI flash are broken on da850-evm, i.e. the data
read is not what is actually programmed on the flash.
According to the datasheet for the M25P64 part present on the da850-evm,
if the SPI frequency is higher than 20MHz then the READ command is not
usable anymore and only the FAST_READ command can be used to read data.

This commit specifies in the DTS that we should use FAST_READ command
instead of the READ command.

Signed-off-by: Fabien Parent <fpar...@baylibre.com>
---
 arch/arm/boot/dts/da850-evm.dts | 1 +
 1 file changed, 1 insertion(+)

diff --git a/arch/arm/boot/dts/da850-evm.dts b/arch/arm/boot/dts/da850-evm.dts
index 41de15fe15a2..78492a0bbbab 100644
--- a/arch/arm/boot/dts/da850-evm.dts
+++ b/arch/arm/boot/dts/da850-evm.dts
@@ -99,6 +99,7 @@
                                #size-cells = <1>;
                                compatible = "m25p64";
                                spi-max-frequency = <30000000>;
+                               m25p,fast-read;
                                reg = <0>;
                                partition@0 {
                                        label = "U-Boot-SPL";
-- 
2.11.0