On Wednesday 18 January 2017 05:55 AM, Kevin Hilman wrote: > Fabien Parent <[email protected]> writes: > >> Read access to the SPI flash are broken on da850-evm, i.e. the data >> read is not what is actually programmed on the flash. >> According to the datasheet for the M25P64 part present on the da850-evm, >> if the SPI frequency is higher than 20MHz then the READ command is not >> usable anymore and only the FAST_READ command can be used to read data. >> >> This commit specifies in the DTS that we should use FAST_READ command >> instead of the READ command. >> >> Signed-off-by: Fabien Parent <[email protected]> > > Tested on da850-evm on top of v4.10-rc3. This gets the DT boot > functionatliy in line with the legacy (board-file) boot. > > Tested-by: Kevin Hilman <[email protected]>
Applied with Kevin's Tested-by and also marked for stable. Sending pull request for v4.10-rc shortly. Thanks, Sekhar