Which OM version is this ?

 

From: [email protected] 
[mailto:[email protected]] On Behalf Of Mohd Noor Abdul Rashid
Sent: Wednesday, January 20, 2010 12:22 PM
To: linux-poweredge-Lists
Subject: OMSA Event message

 

Hi there

I had a customer which depend on OMSA to monitor his Dell server hardware 
status.
Recently he did power supply redundancy test and curious on the event message 
recorded where event id 1354 only comes one while 1306 was repeated several time
Question
1. Is this expected behaviour ? as per my understand the event should be 
recorded in the system message file until it was rectify
2. Why event 1354 recorded only once while event 1306 was recorded multiple 
times ?
3. Customer also seek an explanation why after event id 1306 recorded twice, 
then event id 1354 record only once, whereas event 1354 is more crucial than 
1306
4. Is there any default timing for the message to be re-occur and recorded in 
system message until the problem rectify, so that the message will be recorded 
in standard interval time

Pasted below relevant portion from system message file
=================================================
Jan 14 10:59:09 mzebk01u Server Administrator: Instrumentation Service EventID: 
1306  Redundancy lost  Redundancy unit: System Board PS Redundancy  Chassis 
location: Main System Chassis  Previous redundancy state was: Normal
Jan 14 10:59:09 mzebk01u snmpd[2214]: Got trap from peer on fd 16 
Jan 14 10:59:10 mzebk01u Server Administrator: Instrumentation Service EventID: 
1306  Redundancy lost  Redundancy unit: System Board PS Redundancy  Chassis 
location: Main System Chassis  Previous redundancy state was: Normal
Jan 14 10:59:10 mzebk01u last message repeated 22 times
Jan 14 10:59:10 mzebk01u Server Administrator: Instrumentation Service EventID: 
1354  Power supply detected a failure  Sensor location: PS 1 Status  Chassis 
location: Main System Chassis  Previous state was: OK (Normal)  Power Supply 
type: AC  Power Supply state: Presence detected, Failure detected, AC lost
Jan 14 10:59:10 mzebk01u Server Administrator: Instrumentation Service EventID: 
1306  Redundancy lost  Redundancy unit: System Board PS Redundancy  Chassis 
location: Main System Chassis  Previous redundancy state was: Normal
Jan 14 10:59:10 mzebk01u Server Administrator: Instrumentation Service EventID: 
1306  Redundancy lost  Redundancy unit: System Board PS Redundancy  Chassis 
location: Main System Chassis  Previous redundancy state was: Normal
Jan 14 10:59:10 mzebk01u snmpd[2214]: Got trap from peer on fd 16 
Jan 14 10:59:32 mzebk01u last message repeated 22 times
Jan 14 10:59:33 mzebk01u Server Administrator: Instrumentation Service EventID: 
1304  Redundancy regained  Redundancy unit: System Board PS Redundancy  Chassis 
location: Main System Chassis  Previous redundancy state was: Lost
Jan 14 10:59:33 mzebk01u last message repeated 44 times
Jan 14 10:59:33 mzebk01u Server Administrator: Instrumentation Service EventID: 
1352  Power supply returned to normal  Sensor location: PS 1 Status  Chassis 
location: Main System Chassis  Previous state was: Critical (Failed)  Power 
Supply type: AC  Power Supply state: Presence detected
Jan 14 10:59:33 mzebk01u Server Administrator: Instrumentation Service EventID: 
1304  Redundancy regained  Redundancy unit: System Board PS Redundancy  Chassis 
location: Main System Chassis  Previous redundancy state was: Lost
==============================================================

Can't find relevant answer on dell support site 
http://support.dell.com/support/edocs/software/svradmin/5.4/en/messages/html/index.htm
 and
http://support.dell.com/support/edocs/software/svradmin/5.4/en/index.htm . 

Appreciate for any respond given

Thanks

 

Mohd Noor Abdul Rashid

 

 

_______________________________________________
Linux-PowerEdge mailing list
[email protected]
https://lists.us.dell.com/mailman/listinfo/linux-poweredge
Please read the FAQ at http://lists.us.dell.com/faq

Reply via email to