Hello Michal, Thank you very much. I think it's ok now.
oneohtwo:~# omreport storage vdisk List of Virtual Disks in the System Controller PERC 6/i Integrated (Embedded) ID : 0 Status : Ok Name : Virtual Disk 0 State : Ready Progress : Not Applicable Layout : RAID-5 Size : 408.38 GB (438489317376 bytes) Device Name : /dev/sda Type : SAS Read Policy : No Read Ahead Write Policy : Write Back Cache Policy : Not Applicable Stripe Element Size : 64 KB Disk Cache Policy : Disabled When there is a problem, "Status : Ok" change to "Status : Failure" ? Thanks in advance. Nicolas Le 09-07-21 à 07:12, Lazy a écrit : > 2009/7/21 Nicolas Delanos <[email protected]>: > > >>> Then follow the instructions from nagios exchange to get it >>> monitored from nagios >>> http://pookey.co.uk/blog/archives/48-Monitoring-Dell-SAS-5iR-RAID-with-nagios.html > >>>> >>>> I have a Dell PowerEdge 2950 with debian etch (2.6.18-6-amd64 #1 >>>> SMP Fri Dec 12 05:49:32 UTC 2008 x86_64 GNU/Linux). >>>> >>>> # lspci >>>> 01:00.0 RAID bus controller: LSI Logic / Symbios Logic SAS1078 PCI- >>>> X Fusion-MPT SAS (rev 04) >>>> >>>> I would like to monitor the RAID status. I tried to follow several >>>> tutorial but it doesn't work. Every time I get this error. >>>> >>>> # mpt-status >>>> MPI_FUNCTION_CONFIG (get page header): No such device >>>> >>>> Can you help me ? > > you have a PERC 6/i and mpt-status doesn't support those > > I whould recommend You install omsa > > on debian check > https://subtrac.rc.sara.nl/oss/omsa_2_deb > > before instaling make sure that mptctl is loaded and ipmi is running > (ipmi_si,ipmi_devintf) or omsa will not > be able to monitor other system elements > > afther that you can check raid status using omreport storage vdisk > > -- > Michal Grzedzickie _______________________________________________ Linux-PowerEdge mailing list [email protected] https://lists.us.dell.com/mailman/listinfo/linux-poweredge Please read the FAQ at http://lists.us.dell.com/faq