On 02/14/2017 09:44 PM, Raghava Aditya Renukunta wrote: > During the IOP reset stress testing, it was found that the drives can be > marked offline when the adapter controller crashes and IO's are running > in parallel. When the controller does come back from the reset, the drive > that is marked offline is not exposed. > > Fixed by removing and adding drives that are marked offline. In addition > invoke a scsi host bus rescan to capture any additional configuration > changes. > > Signed-off-by: Raghava Aditya Renukunta > <[email protected]> > Reviewed-by: David Carroll <[email protected]> > ---
Reviewed-by: Johannes Thumshirn <[email protected]> -- Johannes Thumshirn Storage [email protected] +49 911 74053 689 SUSE LINUX GmbH, Maxfeldstr. 5, 90409 Nürnberg GF: Felix Imendörffer, Jane Smithard, Graham Norton HRB 21284 (AG Nürnberg) Key fingerprint = EC38 9CAB C2C4 F25D 8600 D0D0 0393 969D 2D76 0850