> * Menaka Lashitha Bandara ([EMAIL PROTECTED]) [1999-09-06 17:30]:
> > modprobe g_NCR5380 ncr_irq=255 ncr_addr=0x2c0 ncr_53c400=1
> >
> > Both tese failed. It says:
> >
> > scsi0: bus busy, attempting abort
> >
> > and freezes my whole system. Can anyone make any suggestions as to how
> > I can get this working?
>
> I recall that you need to put dtc3181e=1 instead of ncr_53c400=1. Also,
> leaving out the ncr_addr *MIGHT* help.
You want dtc3181e=1 or ncr53c400a=1 - the 53c400 is a different far better
device. (ncr 53c400 owners are probably incredulous at the claim but the
400a is really almost always set up worse still). I use the 400a regularly
with my scanner. It works, kind of , if you pedal hard.
Alan
-