> * Menaka Lashitha Bandara ([EMAIL PROTECTED]) [1999-09-06 17:30]:
> >    modprobe g_NCR5380 ncr_irq=255 ncr_addr=0x2c0 ncr_53c400=1
> >    
> >    Both tese failed. It says:
> >    
> >    scsi0: bus busy, attempting abort
> >    
> >    and freezes my whole system. Can anyone make any suggestions as to how
> >    I can get this working?
> 
> I recall that you need to put dtc3181e=1 instead of ncr_53c400=1. Also,
> leaving out the ncr_addr *MIGHT* help. 

You want dtc3181e=1 or ncr53c400a=1  - the 53c400 is a different far better
device. (ncr 53c400 owners are probably incredulous at the claim but the
400a is really almost always set up worse still). I use the 400a regularly
with my scanner. It works, kind of , if you pedal hard.

Alan


-
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to [EMAIL PROTECTED]

Reply via email to