On Thu, Sep 03, 2026 at 08:38:16AM +0300, Dmitry Guzman wrote: > Controllers without EMPTYFIFO_HOLD_MASTER feature cannot hold bus with > empty FIFO. This makes impossible to issue SMBUS block read command: > it is not known how many bytes must be read until it reads the first byte
Too many spaces. > indicates the data length is read. Without EMPTYFIFO_HOLD_MASTER, when > the first byte is read, TX FIFO gets empty, this causes STOP condition > and the transfer is terminated. > > Reset SMBUS_READ_BLOCK_DATA bit in functionality mask on such controllers. ... > + /* Controllers without EMPTYFIFO_HOLD_MASTER feature cannot issue SMBUS > + * block read because after reading the data length FIFO gets empty and > + * STOP is generated automatically > + */ /* * Please, use the regular style for the * multi-line comments. This reply can be used * as an example. */ -- With Best Regards, Andy Shevchenko