On Thu, Sep 03, 2026 at 08:38:16AM +0300, Dmitry Guzman wrote:
> Controllers without EMPTYFIFO_HOLD_MASTER feature cannot hold bus with
> empty FIFO. This makes impossible to issue SMBUS block read command:
> it is not known how many bytes must be read until it reads the  first byte

Too many spaces.

> indicates the data length is read. Without EMPTYFIFO_HOLD_MASTER, when
> the first byte is read, TX FIFO gets empty, this causes STOP condition
> and the transfer is terminated.
> 
> Reset SMBUS_READ_BLOCK_DATA bit in functionality mask on such controllers.

...

> +     /* Controllers without EMPTYFIFO_HOLD_MASTER feature cannot issue SMBUS
> +      * block read because after reading the data length FIFO gets empty and
> +      * STOP is generated automatically
> +      */

/*
 * Please, use the regular style for the
 * multi-line comments. This reply can be used
 * as an example.
 */

-- 
With Best Regards,
Andy Shevchenko



Reply via email to