On Wed, Feb 19, 2014 at 12:38:59AM +0100, Holzinger, Axel (ALC NetworX GmbH) wrote: > > So this means using the UDS Interface I guess. But does it really make sense > to use UDS for reading a precise time. Is it fast enough?
No, it is not for getting time stamps. For that, you read the PHC device directly, and then convert using values from the UDS message. Perhaps a more realistic use case is to produce a pulse train from the PHC into some other device. The values from the UDS message help you program the other device to properly interpret the signal. Thanks, Richard ------------------------------------------------------------------------------ Managing the Performance of Cloud-Based Applications Take advantage of what the Cloud has to offer - Avoid Common Pitfalls. Read the Whitepaper. http://pubads.g.doubleclick.net/gampad/clk?id=121054471&iu=/4140/ostg.clktrk _______________________________________________ Linuxptp-devel mailing list Linuxptp-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/linuxptp-devel