On Wed, Feb 19, 2014 at 12:38:59AM +0100, Holzinger, Axel  (ALC NetworX GmbH) 
wrote:
> 
> So this means using the UDS Interface I guess. But does it really make sense 
> to use UDS for reading a precise time. Is it fast enough?

No, it is not for getting time stamps. For that, you read the PHC
device directly, and then convert using values from the UDS message.

Perhaps a more realistic use case is to produce a pulse train from the
PHC into some other device. The values from the UDS message help you
program the other device to properly interpret the signal.

Thanks,
Richard

------------------------------------------------------------------------------