T200 is really sensitive to the voltage on the nicad.
On Wednesday, April 15, 2015, John Whitton <[email protected]> wrote: > Without looking at the schematic, the cap may present a much lower impedance than the NiCad, thereby causing a large inrush and possible attendant perturbations in the power when it is first applied. Quite obviously, the abrupt capacitive load is considerably different than the load of a NiCad. > > > John W. > > > > ----- Original Message ----- From: "Kurt McCullum" <[email protected]> > To: "Model 100 Discussion" <[email protected]> > Sent: Wednesday, April 15, 2015 5:25 PM > Subject: [M100] T200 Super Capacitor Warning >> >> However, I tried the same replacement on my 200 today and it caused problems. First, when I plugged in AC power the unit powered up on it's own. Then when I tried to power down, the screen was left with two horizontal lines and the speaker had a low hum. In the end, I cut the leads to the capacitor and I am running without an internal backup battery. This restored everything to normal. > >