So, if you are putting in offers for the wind units, I assume you must be treating them as dispatchable. So you can't treat them as negative loads, they must be generators with PF=1.
-- Ray Zimmerman Senior Research Associate 211 Warren Hall, Cornell University, Ithaca, NY 14853 phone: (607) 255-9645 On Mar 21, 2011, at 12:28 PM, Carlos Gonzalez Almeida wrote: > Dear Prof. Zimmerman > > If I want to do runmarket in a network with offers and bids in presence of > wind turbines how can I simulate wind turbines? because when I simulate wind > turbines as negative load how can I insert offers?is it possible? > Otherwise I have to simulate as generators with PF=1? please help me. > > Best Wishes > > C. Gonzalez Almeida > > > On Mon, Mar 21, 2011 at 17:18, Ray Zimmerman <[email protected]> wrote: > Just use a zero quantity offer for that wind unit. > > -- > Ray Zimmerman > Senior Research Associate > 211 Warren Hall, Cornell University, Ithaca, NY 14853 > phone: (607) 255-9645 > > > > On Mar 21, 2011, at 6:15 AM, Carlos Gonzalez Almeida wrote: > > > Dear Prof. Zimmerman > > > > I want to do runmarket in the case ('t_auction_case') with 6 generators > > including first: 5 wind turbines and 1 generator and second with 4 wind > > turbines and 2 generators. For this, I have used your file that you > > provided to have PF=1 for wind turbines. > > For second case how can I do this? I mean with one of the wind turbines > > with zero wind(cut off). Is it possible?if yes how? > > > > Best Wishes > > > > Carlos > > > >