Yes. All of the parameters of your network matter. It sounds like you have a 
full power system design problem you are working on. You will need to get help 
elsewhere for that problem. This discussion has already gone well beyond the 
normal MATPOWER specific questions this list is intended for.

I suggest you take your remaining questions to a local power systems expert.

-- 
Ray Zimmerman
Senior Research Associate
211 Warren Hall, Cornell University, Ithaca, NY 14853
phone: (607) 255-9645



On Mar 21, 2011, at 1:33 PM, Carlos Gonzalez Almeida wrote:

> But according to your responses in the last emails, there are some other 
> constraints and with any PFs usually I cannot simulate generators with PF=1. 
> I don't know how can I do runmarket with offers and bids?
> 
> On Mon, Mar 21, 2011 at 18:21, Ray Zimmerman <[email protected]> wrote:
> So, if you are putting in offers for the wind units, I assume you must be 
> treating them as dispatchable. So you can't treat them as negative loads, 
> they must be generators with PF=1.
> 
> -- 
> Ray Zimmerman
> Senior Research Associate
> 211 Warren Hall, Cornell University, Ithaca, NY 14853
> phone: (607) 255-9645
> 
> 
> 
> On Mar 21, 2011, at 12:28 PM, Carlos Gonzalez Almeida wrote:
> 
>> Dear Prof. Zimmerman
>> 
>> If I want to do runmarket in a network with offers and bids in presence of 
>> wind turbines how can I simulate wind turbines? because when I simulate wind 
>> turbines as negative load how can I insert offers?is it possible?
>> Otherwise I have to simulate as generators with PF=1? please help me.
>> 
>> Best Wishes
>> 
>> C. Gonzalez Almeida
>> 
>> 
>> On Mon, Mar 21, 2011 at 17:18, Ray Zimmerman <[email protected]> wrote:
>> Just use a zero quantity offer for that wind unit.
>> 
>> --
>> Ray Zimmerman
>> Senior Research Associate
>> 211 Warren Hall, Cornell University, Ithaca, NY 14853
>> phone: (607) 255-9645
>> 
>> 
>> 
>> On Mar 21, 2011, at 6:15 AM, Carlos Gonzalez Almeida wrote:
>> 
>> > Dear Prof. Zimmerman
>> >
>> > I want to do runmarket in the case ('t_auction_case') with 6 generators 
>> > including first: 5 wind turbines and 1 generator and second with 4 wind 
>> > turbines and 2 generators. For this, I have used your file that you 
>> > provided to have PF=1 for wind turbines.
>> > For second case how can I do this? I mean with one of the wind turbines 
>> > with zero wind(cut off). Is it possible?if yes how?
>> >
>> > Best Wishes
>> >
>> > Carlos
>> 
>> 
>> 
>> 
> 
> 
> 
> 
> Best Wishes
> 
> C. Gonzalez Almeida