Thank you for your immediate reply sir. ----- Original Message ----- From: Ray Zimmerman Sent: 11/07/12 10:14 PM To: MATPOWER discussion forum Subject: Re: Reactive power cost function
The reactive power cost in MATPOWER takes the same format as the real power cost. If there are ng generators and the gencost matrix has 2*ng rows, the first ng rows are used to specify the costs for real power and the last ng rows are the corresponding costs for reactive power. -- Ray Zimmerman Senior Research Associate 419A Warren Hall, Cornell University, Ithaca, NY 14853 phone: (607) 255-9645 On Nov 6, 2012, at 11:00 PM, Eezhamalar AT < [email protected] > wrote: Dear sir/mam, In the manual of matpower, for opf problem, the cost function is based on the real and reactive power functions. Real power function is explained clearly. But how can we give the reactive power cost function. what is the format. Please reply me soon. Thanks in advance ---*Malar* ---*Malar*