Thank you for your immediate reply sir.

----- Original Message -----
From: Ray Zimmerman
Sent: 11/07/12 10:14 PM
To: MATPOWER discussion forum
Subject: Re: Reactive power cost function

 The reactive power cost in MATPOWER takes the same format as the real power 
cost. If there are ng generators and the gencost matrix has 2*ng rows, the 
first ng rows are used to specify the costs for real power and the last ng rows 
are the corresponding costs for reactive power. 

-- 

 Ray Zimmerman
 Senior Research Associate
 419A Warren Hall, Cornell University, Ithaca, NY 14853
 phone: (607) 255-9645

 On Nov 6, 2012, at 11:00 PM, Eezhamalar AT < [email protected] > wrote:
Dear sir/mam,
 In the manual of matpower, for opf problem, the cost function is based on the 
real and reactive power functions. Real power function is explained clearly. 
But how can we give the reactive power cost function. what is the format. 
Please reply me soon. Thanks in advance

---*Malar*



---*Malar*

Reply via email to