Dear Ray
would you please send me the codes to find islands in the system?
thanks
xiwen

Sent from my iPhone

On Sep 9, 2013, at 2:56 PM, Ray Zimmerman <[email protected]> wrote:

> The latest development version of MATPOWER has some utilities for finding 
> islands and I have happy to send you the relevant functions off-list if you 
> like. MATPOWER should handle a DC OPF with a system with islands just fine as 
> long as each island has its own reference bus and each island has a feasible 
> solution (e.g. sufficient generation to meet load without overloading lines).
> 
> -- 
> Ray Zimmerman
> Senior Research Associate
> B30 Warren Hall, Cornell University, Ithaca, NY 14853
> phone: (607) 255-9645
> 
> 
> 
> 
> 
> On Sep 8, 2013, at 10:18 PM, Jovan Ilic <[email protected]> wrote:
> 
>> 
>> Does anybody know what happens if part of the system is 
>> disconnected due to programmatically disabling branches.  
>> I'd like to run DCOPF many times while possibly disconnecting 
>> some of the lines. 
>> 
>> Thanks,
>> Jovan Ilic
> 

Reply via email to