Dear Ray would you please send me the codes to find islands in the system? thanks
Maximiliano > The latest development version of MATPOWER has some utilities for finding > islands and I have happy to send you the relevant functions off-list if > you like. MATPOWER should handle a DC OPF with a system with islands just > fine as long as each island has its own reference bus and each island has > a feasible solution (e.g. sufficient generation to meet load without > overloading lines). > > -- > Ray Zimmerman > Senior Research Associate > B30 Warren Hall, Cornell University, Ithaca, NY 14853 > phone: (607) 255-9645 > > > > > > On Sep 8, 2013, at 10:18 PM, Jovan Ilic <[email protected]> wrote: > >> >> Does anybody know what happens if part of the system is >> disconnected due to programmatically disabling branches. >> I'd like to run DCOPF many times while possibly disconnecting >> some of the lines. >> >> Thanks, >> Jovan Ilic > >