Dear all,

I have a follow-up question to a previous email
<http://www.mail-archive.com/[email protected]/msg05428.html> (message
05428). Someone asked about ramp constraints being violated on multi-period
unit commitment runs between t=0 and t=1, and the response was

"Accordingly, MOST does not actually put constraints on the ramping
transitions from t=0 to t=1; if this is really needed, then you need to
modify the Pmax and Pmin of the generators at t=1 based on the ramping
limit and the value of the InitialPg parameter. This might need some
revising of the manual."

I was wondering if someone could provide guidance on how to change the
values of Pmin and Pmax so that they are different between t=0 and t=1. In
the mpc.gen array, it appears that Pmax and Pmin allow only scalar values
for each generator.

Thanks!

Stephen Suffian