Hi
That file includes a statement to create a table called dictionary so it
should be there. If that table is not there text extraction will fail ...
D
On 12/08/2011 02:56 PM, VISIONAIRE-Reza Toghraee wrote:
Yes, I don't have a DICTIONARY table in my database. I created
manually based on mysql5.sql in ddl.
*From:*[email protected]
[mailto:[email protected]] *On Behalf Of
*David Horwitz
*Sent:* Thursday, December 08, 2011 4:32 PM
*To:* [email protected]
*Subject:* Re: [Matterhorn-users] MattherHorn 1.2 and Epiphan Capture
Appliance Updates and Issues -- New User
Also check that is a DICTIONARY table in your database - there is a
known bug that the ddl doesn't always create this table...
D
On 12/08/2011 01:18 PM, Dr Leslaw Zieleznik wrote:
Reza,
You probably need to create your own dictionary?
Below is instruction of how to disable text extraction, recently
published on the list:
**************************************************
Non-authorative answer:
in $FELIX_HOME/conf/workflow/*.xml
remove the following lines:
------------------------------------------
<!-- Run text analysis -->
<operation
id="extract-text"
fail-on-error="false"
exception-handler-workflow="error"
description="Extracting text from presentation segments">
<configurations>
<configuration key="source-flavor">presentation/trimmed</configuration>
<configuration key="source-tags"></configuration>
<configuration key="target-tags">engage</configuration>
</configurations>
</operation>
-------------------------------------------
Leslaw
On 8 Dec 2011, at 11:08, VISIONAIRE-Reza Toghraee wrote:
Dear Dr Leslaw
Thank you very much for your reply.
I had enabled the Audio and attached a mic as well. But today I
realized that the Audio mode was set on Line. I changed it to MIC and
now at least on preview CGI of MCA, I can hear the voice as well.
Currently Im suffering from the OCR. Whenever Im making a recording it
is failing during the Text Extraction. Is there any way to disable the
Text Extraction from the workflow?
Thank you
Reza
*From:*[email protected]
<mailto:[email protected]>[mailto:[email protected]]*On
Behalf Of*Dr Leslaw Zieleznik
*Sent:*Thursday, December 08, 2011 1:00 PM
*To:*Matterhorn Users
*Subject:*Re: [Matterhorn-users] MattherHorn 1.2 and Epiphan Capture
Appliance Updates and Issues -- New User
Hi Reza,
0- till now, after recording more than 10 times, I couldn't manage
to have
the complete result of recording (Video + VGA + Audio) in Engage.
You need to enable the audio and connect the microphone, it will
then start recording all three streams.
1- sometimes when recording has to be finished, the server still
shows that
the MCA is in Capturing state. I don't understand why the status
is not
being updated.
This is know bug, MCA sits in the capture state (the workflow is
showing PAUSE) for about 35min and then will do the ingestion.
In summary the device is capturing nicely if you take the above into
account - see also below.
There is more information about the device behave on the Matterhorn
Users list.
3- almost most of the times, when the MCA ingests the file to the
Core and
Core starts digesting, usually it fails in 'Text Extraction"
Phase. Is there
any way to skip the text extraction phase while digesting?
I have no problem with this, only the text OCR is not very accurate.
Calendar Polling Interval: 1 minuet
Agent State Push Interval: 60 seconds
Ingest Interval : 2 minutes (I changed it from 60 minutes to 2
minute to
speedup the ingest)
I am using a similar setup: 2, 60, 5.
Best,
Leslaw
_______________________________________________
Matterhorn-users mailing list
[email protected]
<mailto:[email protected]>
http://lists.opencastproject.org/mailman/listinfo/matterhorn-users
_______________________________________________
Matterhorn-users mailing list
[email protected]
http://lists.opencastproject.org/mailman/listinfo/matterhorn-users
_______________________________________________
Matterhorn-users mailing list
[email protected]
http://lists.opencastproject.org/mailman/listinfo/matterhorn-users