Steve,
 
Look in the @ARC section of your template (TMP) file. Change I#XCTR J#YCTR to R#ARAD. Depending on the control you may want to add some logic to test for an arc greater than 180 degrees, or 360 degrees. Ask again for more help.
 
Regards,
 
Bill.
----- Original Message -----
Sent: Tuesday, April 01, 2003 7:39 PM
Subject: [mfg-smartcam] Radius or I,J,K

Group,

 

            Good morning, I am almost ashamed to even ask this but can someone please tell where to indicate whether or not to use �R� value or I�s and J�s for arc radii. I thought it was just a yes or no in the machine define but I can�t seem to find it. That is one of the things about smartcam, once you get things set and tweaked in you never have to change them. So in short I have forgotten where a lot of these things are. Thanks in advance  

 

Steve Chastain

Viper Northwest

Phn: 541-928-2529

Fax: 541-928-1526

 