Hi, Am 11.06.2012 14:11, schrieb s.ferey: > however yes a specific service, or the definition of a new constant for > the SCardGetStatusChange function (afaik only 11 over 32 bits of the > dwCurrentState field are used), or a tag for the SCardGetAttrib > function, could be an easy & efficient way to know if the communication > is over-the-air or not.
sorry, I missed the start of this discussion. Isn't it possible to use SCardGetAttrib with Tags 0121 or 0122 (default and max clock, respectively, special result of 13560 for contactless) or with 0150 (mech. characteristics, bitfield, 00000008 means contactless)? (see PC/SC pt 3, section 3.1.1.2) HTH Regards, Frank Peters _______________________________________________ Muscle mailing list [email protected] http://lists.drizzle.com/mailman/listinfo/muscle