Good question. The failure mechanism is certainly there. In thermionic valves 'dumet' glass to metal seals are used to match the expansion coefficient of the glass to that of the wire. I am not sure if anything similar is used for nixies that run much cooler. Anyone knows what the wire leads are made of?
In any case, if in doubt you can attach a small clamp (like a croc clip) to sink heat away from the glass-metal seal. Alex On Sep 5, 9:38 pm, Adam Jacobs <[email protected]> wrote: > I've always soldered the leads of IN-14's, never gave it much consideration. > Never had a problem. I think that the thing you want to avoid is soldering > the nixies which need sockets. IN-8's, IN-12's, IN-18's, that kind of thing. > The ones with flying leads are _designed_ to be soldered. > > -Adam > > On Mon, Sep 5, 2011 at 11:19 AM, Ryan McDonald <[email protected]>wrote: > > > I've heard that soldering the leads on IN-14's can cause premature > > seal failure. I've also heard that staying at least 5mm from the > > glass largely mitigates this problem. Can anyone make any > > recommendations concerning the soldering (or makeshift socketing) of > > IN-14's? > > > -- > > You received this message because you are subscribed to the Google Groups > > "neonixie-l" group. > > To post to this group, send an email to [email protected]. > > To unsubscribe from this group, send email to > > [email protected]. > > For more options, visit this group at > >http://groups.google.com/group/neonixie-l?hl=en-GB. -- You received this message because you are subscribed to the Google Groups "neonixie-l" group. To post to this group, send an email to [email protected]. To unsubscribe from this group, send email to [email protected]. For more options, visit this group at http://groups.google.com/group/neonixie-l?hl=en-GB.