Hi, I've encountered an issue like this before with flowvisor and the discovery module. The easiest thing to do is to change the lldp value in
./src/nox/lib/packet/ethernet.py #LLDP_TYPE = 0x88cc LLDP_TYPE = new_value then add this new_value, ether_type to your slice. Hopefully that will do the trick. Aaron 2012/1/12 Sergio Jiménez Feijóo <jjji...@gmail.com> > Hi guys, > > I've developed a NOX aplication which needs to use the topology component > to discover the network topology. I've tested my application in a testbed > of 6 Linksys WRT54GL running the OpenWRT Pantou firmware (without > flowvisor) and it worked like a charm. Now I'm testing my aplication in a > testbed of 5 NEC IP8800/S3640-24T2XW (with flowvisor) and the topology > detection isn't working at all (the data struct is empty). > > Since OpenFlow allows an application to run in different devices I've > discarded the fact of using new switches as the cause of the error. > Therefore I think flowvisor is causing the topology component not to run > properly. Is this possible? Have you experienced any problems with > flowvisor and NOX? > > Thank you. > > http://homestore.cisco.eu/**store/ciscoeu/en_IE/pd/**productID.241269400<http://homestore.cisco.eu/store/ciscoeu/en_IE/pd/productID.241269400> > http://www.openflow.org/wk/**index.php/Pantou_:_OpenFlow_1.**0_for_OpenWRT<http://www.openflow.org/wk/index.php/Pantou_:_OpenFlow_1.0_for_OpenWRT> > http://yuba.stanford.edu/**foswiki/bin/view/OpenFlow/** > Deployment/Vendor/NEC<http://yuba.stanford.edu/foswiki/bin/view/OpenFlow/Deployment/Vendor/NEC> > > ______________________________**_________________ > nox-dev mailing list > nox-dev@noxrepo.org > http://noxrepo.org/mailman/**listinfo/nox-dev<http://noxrepo.org/mailman/listinfo/nox-dev> > -- Aaron O. Rosen Masters Student - Network Communication 306B Fluor Daniel
_______________________________________________ nox-dev mailing list nox-dev@noxrepo.org http://noxrepo.org/mailman/listinfo/nox-dev