Please run DCPROMO and remove AD from it before rebuilding it. Although that is assuming that you have other DC's in your AD structure. Removing AD from the DC needing to be rebuilt would be for the benefit of the other DC's, and you will need to make sure that your FSMO roles are assigned correctly - any FSMO roles this DC currently has would need to be reassigned. Do that before removing AD (obviously, since you can't do it after). If you only have the one DC, do whatever you want. I suppose that a bit more information would be in order.
James Winzenz, MCSE, A+ Associate Systems Administrator Peregrine Systems, Inc. -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]] Sent: Thursday, March 21, 2002 3:52 AM To: NT 2000 Discussions Subject: DC rebuild I have a DC that needs a rebuild.... Do I need to remove AD before I trash it, or can I simply rebuild it and then run DCPROMO again? I have done this before in the test lab and had no obvious problems. Any Ideas or thoughts? Thanks in advance, Robert Rutherford MIS Department - DEK International GmbH +44 (0)1305 208232 +44 (0)7970 122362 **************************************************************************** **************** This E-mail and any files transmitted with it are in commercial confidence and intended solely for the use of the individual or entity to whom they are addressed. If you have received this E-mail in error please notify the Administrator by E-mail ([EMAIL PROTECTED]). Any views or opinions expressed are solely those of the author and do not necessarily represent those of DEK Printing Machines Ltd., or its affiliates. **************************************************************************** **************** ------ You are subscribed as [EMAIL PROTECTED] Archives: http://www.swynk.com/sitesearch/search.asp To unsubscribe send a blank email to %%email.unsub%% ------ You are subscribed as [email protected] Archives: http://www.swynk.com/sitesearch/search.asp To unsubscribe send a blank email to [EMAIL PROTECTED]