739.548074 hu_find_infoval: found chrg (value: 1) 739.548141 process_boolean_info: chrg
739.548177 Report[buf]: (2 bytes) => 16 05 739.548209 PhyMax = 0, PhyMin = 0, LogMax = 1, LogMin = 0 739.548239 Unit = 00000000, UnitExp = 0 739.548272 Exponent = 0 739.548307 Path: UPS.PowerSummary.PresentStatus.Discharging, Type: Feature, ReportID: 0x16, Offset: 3, Size: 1, Value: 0 739.548362 hu_find_infoval: found !dischrg (value: 0) 739.548393 process_boolean_info: !dischrg 741.294400 upsdrv_updateinfo... 741.545303 libusb_get_interrupt: Connection timed out 741.545349 Got 0 HID objects... 741.545365 Quick update... 741.545377 Entering libusb_get_report 741.547308 Report[get]: (2 bytes) => 16 05 741.547374 PhyMax = 0, PhyMin = 0, LogMax = 1, LogMin = 0 741.547388 Unit = 00000000, UnitExp = 0 741.547399 Exponent = 0 741.547437 Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Feature, ReportID: 0x16, Offset: 0, Size: 1, Value: 1 741.547451 hu_find_infoval: found online (value: 1) 741.547463 process_boolean_info: online 741.547477 Report[buf]: (2 bytes) => 16 05 741.547488 PhyMax = 0, PhyMin = 0, LogMax = 1, LogMin = 0 741.547500 Unit = 00000000, UnitExp = 0 741.547510 Exponent = 0 741.547523 Path: UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit, Type: Feature, ReportID: 0x16, Offset: 1, Size: 1, Value: 0 741.547536 hu_find_infoval: found !lowbatt (value: 0) 741.547547 process_boolean_info: !lowbatt 741.547560 Report[buf]: (2 bytes) => 16 05 741.547572 PhyMax = 0, PhyMin = 0, LogMax = 1, LogMin = 0 741.547583 Unit = 00000000, UnitExp = 0 741.547593 Exponent = 0 741.547605 Path: UPS.PowerSummary.PresentStatus.Charging, Type: Feature, ReportID: 0x16, Offset: 2, Size: 1, Value: 1 741.547618 hu_find_infoval: found chrg (value: 1) 741.547628 process_boolean_info: chrg 741.547641 Report[buf]: (2 bytes) => 16 05 741.547652 PhyMax = 0, PhyMin = 0, LogMax = 1, LogMin = 0 741.547664 Unit = 00000000, UnitExp = 0 741.547674 Exponent = 0 741.547687 Path: UPS.PowerSummary.PresentStatus.Discharging, Type: Feature, ReportID: 0x16, Offset: 3, Size: 1, Value: 0 741.547699 hu_find_infoval: found !dischrg (value: 0) 741.547710 process_boolean_info: !dischrg 743.296200 upsdrv_updateinfo... 743.547455 libusb_get_interrupt: Connection timed out 743.547503 Got 0 HID objects... 743.547519 Quick update... 743.547532 Entering libusb_get_report 743.549447 Report[get]: (2 bytes) => 16 05 743.549490 PhyMax = 0, PhyMin = 0, LogMax = 1, LogMin = 0 743.549504 Unit = 00000000, UnitExp = 0 743.549515 Exponent = 0 743.549530 Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Feature, ReportID: 0x16, Offset: 0, Size: 1, Value: 1 743.549544 hu_find_infoval: found online (value: 1) 743.549556 process_boolean_info: online 743.549571 Report[buf]: (2 bytes) => 16 05 743.549583 PhyMax = 0, PhyMin = 0, LogMax = 1, LogMin = 0 743.549595 Unit = 00000000, UnitExp = 0 743.549606 Exponent = 0 743.549619 Path: UPS.PowerSummary.PresentStatus.BelowRemainingCapacityLimit, Type: Feature, ReportID: 0x16, Offset: 1, Size: 1, Value: 0 743.549632 hu_find_infoval: found !lowbatt (value: 0) 743.549643 process_boolean_info: !lowbatt 743.549657 Report[buf]: (2 bytes) => 16 05 743.549669 PhyMax = 0, PhyMin = 0, LogMax = 1, LogMin = 0 743.549680 Unit = 00000000, UnitExp = 0 743.549690 Exponent = 0 743.549703 Path: UPS.PowerSummary.PresentStatus.Charging, Type: Feature, ReportID: 0x16, Offset: 2, Size: 1, Value: 1 743.549716 hu_find_infoval: found chrg (value: 1) 743.549726 process_boolean_info: chrg 743.549739 Report[buf]: (2 bytes) => 16 05 743.549751 PhyMax = 0, PhyMin = 0, LogMax = 1, LogMin = 0 743.549762 Unit = 00000000, UnitExp = 0 743.549772 Exponent = 0 743.549785 Path: UPS.PowerSummary.PresentStatus.Discharging, Type: Feature, ReportID: 0x16, Offset: 3, Size: 1, Value: 0 743.549797 hu_find_infoval: found !dischrg (value: 0) 743.549808 process_boolean_info: !dischrg These are my other logs can anybody help me?
_______________________________________________ Nut-upsdev mailing list [email protected] http://lists.alioth.debian.org/cgi-bin/mailman/listinfo/nut-upsdev