On 08/06/2013 05:48 PM, Chris Leech wrote: > I've been doing some digging into a reported scenario where a node > update fails with an "iSCSI database failure" reported. > > The short of it is that it's possible to create node records for a > target portal in both the old-style portal configuration file format, > and the new-style configuration directory with tpgt. If they both exist > on an update command a database failure may occur, depending on the > unspecified return order of readdir.
Just to make sure I am on the same page you have something like: [root@fio iqn.2012-06.com.noisy:tgt1]# ls -l total 16 -rw-------. 1 root root 1764 Aug 9 15:29 10.50.230.117,3260 drw-------. 2 root root 4096 Aug 9 15:30 10.50.230.117,3260,1 One created from the discovery command and the other created from iscsiadm -m node -p 10.50.230.117:3260 -T iqn.2012-06.com.noisy:tgt1 -o new > > If the old-style record is created first, then the update/rewrite logic > will remove it when a request to create a node with a specified tpgt > comes in. But if the new-style record exists first, you can still > create a static old-style record without tpgt. > > On an update, when walking through the files in the node database if > readdir returns the new-style record first this can occur; The > new-style entry is read and passed to idbm_node_set_param and then > idbm_rec_write. In idbm_rec_write the existence of the old-style file > is detected, and it's removed in order to update to the new-style. We > have now gone from two node records to one. > > But, because readdir can cache directory contents from the last > opendir/rewinddir call (in idbm_for_each_portal) it will still return > the path to the now deleted old-style file. Attempting to read that in > (in idbm_for_each_iface) will result in a failed stat call and the > "iSCSI database failure." > > The actual set of calls that seems to be happening in what was reported > to me is running SendTargets discovery on a portal, then for some reason > running additional node --op=new commands specifying the target-name and > portal address (without tpgt) of what was discovered, and finally an > update to change node.startup. To reproduce this reliably, I've been > using LD_PRELOAD with Ted T'so's spd_readdir.c code to cache and sort > the filestream contents. > > OK, arguably that may be a case of "if it hurts when you do that, then > stop doing that." But it's easy, subtle, and weird enough that it might > be worth addressing. It's just not clear how to best address it. > > The idbm code could be more forgiving of stat failures in these loops, > either ignoring them or restarting the command if a filesystem change > like this happens. In this case, it could check for the existence of a > matching new-style entry, and convert that to a static record preserving > the tpgt instead of adding a new static record without one. I think this would be ok. There should not be 2 entries. One question I have is does it cache for different instances of iscsiadm or is a per process type of caching? If one instance of iscsiadm is running some commands and so is another then locking would not prevent issues where one instance is getting stale info. Is there any call we can do to not get cached info? Something like O_DIRECT but for metadata? On a side note if you want to go wild: That iscsi db code is really crusty. The iterator stuff is out of hand. Could we just rewrite it and forget the old formats. To support old setups, can we just do a script that gets run on startup or install that converts the old style to the new one? -- You received this message because you are subscribed to the Google Groups "open-iscsi" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To post to this group, send email to [email protected]. Visit this group at http://groups.google.com/group/open-iscsi. For more options, visit https://groups.google.com/groups/opt_out.