> On Nov 7, 2017, at 8:44 AM, Xingjun Chu <[email protected]> wrote:
> 
> Hi Luis,
> 
> Thanks for the tips first. 
> 
> But for the vlan match, is there a way to say " there is no vlan header", so 
> I can push a vlan. I know I can check the type but is there a way to say vlan 
> is not present.

just set vlan-id-present=false and skip vlan-id:

                                   "vlan-match": {
                                       "vlan-id": {
                                           "vlan-id-present": false
                                       }
                                   },



> 
> Thanks
> Xingjun
> 
> 
> -----Original Message-----
> From: Luis Gomez [mailto:[email protected]] 
> Sent: Sunday, November 05, 2017 11:04 PM
> To: Xingjun Chu <[email protected]>
> Cc: [email protected]; 
> [email protected]; [email protected]
> Subject: Re: [openflowplugin-dev] A question regarding VLAN tagging and 
> untagging
> 
> 
> 
>> On Nov 5, 2017, at 5:18 PM, Xingjun Chu <[email protected]> wrote:
>> 
>> hi Luis
>> 
>> thanks.
>> 
>> is there a way to define a wild card match for example for any vlan header? 
>> doesnt have to be a specific one ? if there is an example code even better. 
> 
> yes, just set vlan-id-present=true and skip vlan-id:
> 
>                                    "vlan-match": {
>                                        "vlan-id": {
>                                            "vlan-id-present": true
>                                        }
>                                    },
> 
> 
>> 
>> i tried to set a vlan match for example vlan id 100. when it is installed,  
>> the match entry in the ovs flow showd a vlan tci match with a vid 100 and a 
>> mask 1fff, i have no idea how the mask is set and by who, which doesnt 
>> actually match  vlan 100 traffic for some reason.
> 
> I think these are OVS specifics, so I would recommend to check OVS 
> documentation.
> 
>> 
>> thanks
>> Xingjun
>> --------------------------------------------------
>> Xingjun Chu Xingjun Chu
>> M:
>> E: [email protected]
>> 2012实验室-渥太华光系统能力中心
>> 2012 Laboratories-Ottawa Optical System Competency Centre
>> 发件人:Luis Gomez
>> 收件人:Xingjun Chu,
>> 抄 
>> 送:[email protected],[email protected],[email protected],
>> 时间:2017-11-05 19:44:18
>> 主 题:Re: [openflowplugin-dev] A question regarding VLAN tagging and untagging
>> 
>> Hi Xingjun, AFAIR you have to specify VLAN match when you set or pop vlan, 
>> not when you push.
>> 
>> 
>>> On Nov 5, 2017, at 7:13 AM, Xingjun Chu <[email protected]> wrote:
>>> 
>>> BTW,
>>> 
>>> On top of the previous email, as an example, here is the  flow table with 
>>> vlan pop action I dumped using openflow rest api. it is in config, but not 
>>> installed.
>>> 
>>> {
>>>    "flow-node-inventory:table": [
>>>        {
>>>            "id": 80,
>>>            "flow": [
>>>                {
>>>                    "id": "DEFAULT_PIPELINE_FLOW_80",
>>>                    "hard-timeout": 0,
>>>                    "idle-timeout": 0,
>>>                    "match": {},
>>>                    "instructions": {
>>>                        "instruction": [
>>>                            {
>>>                                "order": 0,
>>>                                "apply-actions": {
>>>                                    "action": [
>>>                                        {
>>>                                            "order": 0,
>>>                                            "pop-vlan-action": {}
>>>                                        }
>>>                                    ]
>>>                                }
>>>                            },
>>>                            {
>>>                                "order": 1,
>>>                                "go-to-table": {
>>>                                    "table_id": 110
>>>                                }
>>>                            }
>>>                        ]
>>>                    },
>>>                    "barrier": true,
>>>                    "priority": 0,
>>>                    "table_id": 80,
>>>                    "flow-name": "DEFAULT_PIPELINE_FLOW_80"
>>>                }
>>>            ]
>>>        }
>>>    ]
>>> }
>>> 
>>> 
>>> thanks
>>> Xingjun
>>> From: Xingjun Chu
>>> Sent: Sunday, November 05, 2017 9:28 AM
>>> To: [email protected]; 
>>> [email protected]
>>> Cc: [email protected]
>>> Subject: A question regarding VLAN tagging and untagging 
>>> 
>>> Hi, 
>>> 
>>> I have a couple of questions regarding the VLAN relevant action.
>>> 
>>> 1) I have a table in the pipeline which does some L3 forwarding. it has 
>>> some entries to match dst ip, then modify dst dl address, dec-ttl, 
>>> resubmit. etc...  Those flows get installed without problem.
>>> . 
>>> Now I try to add a "VLAN strip or pop" into the action list of the flow 
>>> above for example as the first action , strip or pop VLAN, then modify dst 
>>> dl address, dec-ttl,  resubmit, etc...  I tried both strip or pop action, 
>>> but either way the flow didn't get installed. why is that?    
>>> 
>>> I even tried to just create a separate table with VLAN strip and resubmit 
>>> as the default entry, it doesn't get installed either.
>>> 
>>> 2) also I found more strange thing is that If I need to push and set a VLAN 
>>> ID in the action, Ihave to have a VLAN match first, otherwise 
>>>    the flow is not get installed.   
>>> 
>>> BTW I am doing this NOT using REST API of openflowplugin. but 
>>> programmatically using Action, Action builder  etc...
>>> 
>>> Any pointer is greatly appreciated.
>>> 
>>> Thanks & Regards
>>> Xingjun
>>> 
>>> 
>>> 
>>> 
>>> _______________________________________________
>>> openflowplugin-dev mailing list
>>> [email protected]
>>> https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev
> 

_______________________________________________
openflowplugin-dev mailing list
[email protected]
https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev

Reply via email to