Hi Lars,

New simulator is having better results as for as hpib-test is concerned.
Here are some of my observations with the testing.

1. Looks like the debug option is turned on by default in the new
simulator plugin. This could be off.

2. Once the new_simulator code is merged the old simulator information
could be removed from the openhpi.conf

3. I do not understand the need for the log file in the openhpi.conf.
More over even if I define two logfiles for 2 new_simulator entries, it
takes only one. 

4. The default simulation.data needs to have complete entity path for
every entity. But there are few that do not have the base path now. They
are mis-interpreted now, based on the path defined in the openhpi.conf.
They are {SYSTEM_BOARD,1}, {DISK_DRIVE,2} in the ANNUNCIATOR/RDR_DETAIL.
They get converted to {SYSTEM_BOARD,X}, {DISK_DRIVE,X} (X is 9 in my
test case) as {SYSTEM_CHASSIS,1} is prefixed to these. These could be
seen in the output of hpigensimdata

5. timestamps are changed in the hpigensimdata output too.

I will be doing more testing. Will report the results to you as I find
out more.

Thanks
Mohan

-- 