> > We have an STR712 board by Olimex but (actually, an IAR > kickstart board). We can do the "halt reset" with no errors > but it does not do a clean reset (the PC does not go to > zero). With soft_reset_halt it does go back to zero. There > are no errors logged in either case. > soft_reset_halt just gives a cleaner reset. > > However, halt reset gives a clean reset with STM32 boards and > I use it for them. > > Also, when we put in the reset_config ... shown above the > debug session becomes non-functional but no openocd errors are logged. > > -gene
Because the str7 has the srst and trst tied internally a reset halt will never halt @ 0. A reset halt on this device will always be a 'reset run' then 'halt' command - so a few instructions will always be executed. This is why people often put a small reset delay in the startup file for the str7 to compensate for this. Other cores such as stm32 or str9 will reset correctly @ 0 when a 'reset halt' is issued. Cheers Spen _______________________________________________ Openocd-development mailing list [email protected] https://lists.berlios.de/mailman/listinfo/openocd-development