>> There are no special EuroISDN for T1 in ETSI that would be different
>> from an E1. I don't even think ETSI has a T1 spec?
>
> It can be hard to find specifications in the ETSI system, because  
> their
> document naming and search facilities are somewhat lacking. I never
> understood why it was specified, or who might use it. However,  
> there are
> specific ETSI documents for EuroISDN over T1. I've stumbled on them in
> the past and been puzzled. As far as I recall, they say little that is
> surprising. Its just the same as over E1, but the last channel in
> channel D, and the maximum B channel are only 0 to 22.

for curiosity, how can an E1 bus handle a Bchan on TS 0? I thought  
that was dedicated for timesync?

roy
---