On 2013-05-14 2:30 PM, Andrew McDonnell wrote: > > This patch allows a board to enable the mdio bus on the second ethernet port > provided by the AR7242 (as used in the D-Link DIR-632-A1.) The AR7242 (at > least on the dir632) has two ethernet, eth0 at 0x19000000 and eth1 at > 0x1a000000, and both have enumerable mdio busses. > > It further defaults to connecting eth1 to ag71xx-mdio.1 when registering eth1 > with ath79 platform data. > > Please note this superseded prior email with missing subject(!) Are you sure about this? In other AR724x SoCs one MDIO bus goes to the built-in switch, and the other one is external. You don't seem to make use of the second MDIO bus in your DIR-632-A1 patch either. I think the AR7242 does not have the built-in switch, so it would surprise me to see a second MDIO bus being used there.
- Felix _______________________________________________ openwrt-devel mailing list [email protected] https://lists.openwrt.org/mailman/listinfo/openwrt-devel