At the end I'll do a pull request for opm-core to add this minimum working example with both injectors and producers. I think it's really important for new users/contributors.
Sincerely, Júlio. 2013/12/19 Júlio Hoffimann <[email protected]> > Hi Roland, > > Could you please make the modifications you have in mind? I compiled with > the latest version of OPM from Github and the updated code is at > http://codepad.org/XmmGKKwP > > I just want the injector rate to be fixed at a particular rate. I'll try > to grasp the append_well_controls() function you mentioned. > > Sincerely, > Júlio. > > > 2013/12/19 Roland Kaufmann <[email protected]> > >> [Sorry if this reply is now totally out of the context of the discussion; >> our spam filter has currently instituted a boycott of the OPM mailing list, >> so I may not have seen all replies] >> >> >> On 2013-16-05 17:05, Júlio Hoffimann wrote: >> >>> How do I specify the injection rate for the injector well at the >>> center of the reservoir? (http://codepad.org/A2UoMzR5) >>> >> >> On line 162 (of the original code) you set the control mode of the >> injection well to be BHP (bottom-hole pressure). If I understand you >> correctly, you also want to have a RESV (reservoir rate) constraint. >> >> I think you must append_well_controls() with type=RESERVOIR_RATE. >> >> Also make sure you have a version after opm/opm-core#396 was merged. >> >> -- >> Roland. >> >> >> _______________________________________________ >> Opm mailing list >> [email protected] >> http://www.opm-project.org/mailman/listinfo/opm >> > >
_______________________________________________ Opm mailing list [email protected] http://www.opm-project.org/mailman/listinfo/opm