On Dec 30, 2007 5:41 PM, Paul Alfille <[EMAIL PROTECTED]> wrote: > Are you sure the humidity sensor is HIH-3610?
I just checked the type attribute in owfs itself. What else do I need to look at to confirm this? I'll try to look up the info in the manufacturer's datasheets. (we bought some prepackaged sensors) > We can certainly clip the values to 0-100 but I want to make sure that there > isn't an error, and that there isn't lost information if we do that. Yes, makes sense. It would seem that if the humidity is calculated by multiplying a voltage by a constant we should clip to 0-100 because fluctuations might make it go over 100 even with correct calculations. But of course we don't want to do that if 120% is actually really 100%. Pedro. ------------------------------------------------------------------------- This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2005. http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/ _______________________________________________ Owfs-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/owfs-developers